Specifications

Acoustical (each loudspeaker)
Operating Frequency Range (1)
...

±4 dB from 65 Hz to 18 kHz

...

-6 dB at 60 Hz and 20 kHz

Phase Response (1)
...

±30° from 450 Hz to 10 kHz

Maximum SPL (1)
...

140 dB @ 1 meter

Dynamic Range
...

> 110 dB

Coverage
...

40° Horizontal x 35° vertical

Crossover
...

800 Hz

Transducers
Low Frequency
...

12" Cone driver

High Frequency
...

2" Throat, 4" diaphragm compression driver

Audio Input
Type
...

10 k ohm impedance, electronically balanced

Connector
...

Female XLR input and male XLR loop output or VEAM

Nominal Input Level
...

+4 dBu

Amplifiers
Type
...

Complementary power MOSFET output stages (audio class AB/H)

Burst Capability (2)
...

1240 Watts (620 watts/channel)

THD, IM, TIM
...

< .02 %

AC Power
Connector
...

250V NEMA L6-20 (Twistlock) inlet, IEC 309 male inlet or VEAM(3)

Automatic Voltage Selection
...

85 - 134 VAC; 165 - 264 VAC; 50/60 Hz (4)

Operational Voltage Range
...

Turn on: 85 VAC; Turn off: 134 VAC; 50/60 Hz

...

Turn on: 165 VAC; Turn off: 264 VAC; 50/60 Hz

Max.Continuous RMS Current (> 10 sec)
...

at 115 V: 8 A rms
at 230 V: 4 A rms
at 100 V: 10 A rms

Burst RMS Current (< 1 sec)
...

at 115 V: 15 A rms
at 230 V: 8 A rms
at 100 V: 18 A rms

Max Peak Current During Burst
...

at 115 V: 22 A pk
at 230 V: 11 A pk
at 100 V: 25 A pk

Inrush current
...

< 12 A at 115 V

Physical
Dimensions
...

21.26" w x 36.00" h x 30.00" d
(540 mm x 914 mm x 762 mm)

Weight
...

180 lbs (81.67 kg); Shipping: 215 lbs (97.52 kg)

Enclosure
...

Multi-ply hardwood

Finish
...

Black textured

Protective Grille
...

Hex perforated metal screen, foam covering

Rigging
...

Aircraft pan fittings, three on both top and bottom. Working load for each fitting is 600 lbs, which is 1/5 the cabinet breaking strength (with straight tensile pull).

Notes

1. Subject to half-space loading, measured with one-third octave frequency resolution in fixed ISO bands.

2. Nominal 8 ohm resistive load, pink noise, 100 V peak.

3. Other connectors available. For European applications, the IEC 309 (16A) panel is used.

4. The unit is rated at 88-125 V and 182-235 V, 50/60 Hz, to satisfy EC standards for -10% to 6% AC line voltage.

 

 

 

 

Specifications

Datasheet (PDF)

Operating Instructions (PDF)

Options

QuickFly Rigging

 

 

AutoCAD Files
3D / 2D