| Acoustical (each loudspeaker) |
|
Operating Frequency Range
|
...
|
-6 dB 30 Hz - 125 Hz
|
|
|
|
± 3 dB 32 Hz - 100 Hz (1)
|
|
Phase Response
|
... |
±50° 40 Hz - 130 Hz (2)
|
|
Maximum SPL
|
... |
143 dB @ 1 meter (3)
|
|
Dynamic Range
|
... |
> 110 dB
|
|
| Coverage |
|
|
... |
Cardioid response pattern with > 15 dB front-to-back ratio.
|
|
| Transducers |
|
Low Frequency
|
...
|
Two 18" cone drivers
Four 15" cone drivers
|
|
| Audio Input |
|
Type
|
...
|
5 k ohm impedance, electronically balanced
|
|
Connector
|
... |
Female XLR input and male XLR loop output or VEAM
|
|
Nominal Input Level
|
... |
+4 dBu (1.23 Vrms)
|
|
| Amplifiers |
|
Type
|
...
|
Complementary power MOSFET output stages, class AB/H
|
|
Burst Capability
|
... |
2480 Watts (620 Watts / channel)(4)
|
|
THD, IM, TIM
|
... |
< .02 %
|
|
| AC Power |
|
Connector
|
...
|
250V NEMA L6-20 (Twistlock) inlet, IEC 309 male inlet or
VEAM(5)
|
|
Automatic Voltage Selection
|
... |
85 - 134 VAC; 165 - 264 VAC; 50/60 Hz (6)
|
|
Operational Voltage Range
|
... |
Turn on: 85 VAC; Turn off: 134 VAC; 50/60 Hz
|
|
|
... |
Turn on: 165 VAC; Turn off: 264 VAC; 50/60 Hz
|
|
Max.Continuous RMS Current (>10 sec)
|
... |
at 115 V: 14 A rms
at 230 V: 7A rms
at 100V: 16A rms
|
|
Burst RMS Current (<1 sec)
|
... |
at 115 V: 26 A rms
at 230 V: 13 A rms
at 100 V: 30 A rms
|
|
Max Peak Current During Burst
|
... |
at 115 V: 36 A pk
at 230 V: 18 A pk
at 100 V: 42 A pk
|
|
Inrush Current
|
... |
< 12 A at 115 V
|
|
| Physical |
|
Dimensions
|
... |
42.62" w x 42.86" h x 31.25" d
(1083 mm x 1089 mm x 794 mm)
|
|
Weight
|
... |
442 lbs (200.49 kg); Shipping: 513 lbs (232.70 kg)
|
|
Enclosure
|
... |
12-ply hardwood
|
|
Finish
|
... |
Black textured
|
|
Rigging
|
... |
Twelve pivoting lift rings (6 on top and bottom); working
load for each ring is 1,500 lbs with straight tensile pull.
Safety factor is 5:1. Entire cabinet is reinforced with steel
girders.
|
|
| Notes |
|
1. Twenty-fourth octave, half-space measurement.
2. From pure delay.
3. Peak, in half-space.
4. Nominal 8 ohm resistive load, pink noise, 100V peak.
5. Other connectors available.
6. The unit is rated at 95-125 VAC and 208-235 VAC, 50/60 Hz, to
satisfy EC standards for -10% to 6% AC line voltage.
|