| Maximum Loudspeaker Nodes: |
|
... |
Twisted-pair system with a maximum of 62 nodes (maximum of 50 recommended); up to 115 nodes with a network repeater |
|
... |
Ethernet network with i.LON 10 with up to 50 nodes per network segment |
|
| Maximum Network length without installation of repeater(s): |
|
... |
Free Topology: 20 AWG, 18 AWG or 16 AWG cable, one 52.3 ohm type terminator: 500 m (1,640 ft) |
|
... |
Ethernet: 10BASE-T network limitations plus Standard twisted pair limitations |
|
| Termination: |
|
... |
Free Topology: One 52.3 ohm type terminator at any point |
|
| Cable and Connector Type: |
|
... |
Category 5 or higher. Straight-through (patch) cable if using a hub or a switch. Use a crossover cable if wiring the computer's Ethernet port directly to an i.LON 10. |
|
| Twisted-Pair Cable Type: |
|
... |
20 AWG (Belden 8205 or equivalent) twisted pair, stranded, unshielded |
|
| Connector Types: |
|
... |
Twisted pair: Weidmuller 2 conductor locking connector |
|
... |
Ethernet: 10BASE-T, type RJ-45 |
|
... |
Portable: XLR and EN3 |
|
| Network Platform: |
|
... |
Differential Manchester Encoding; Polarity Insensitive, Free Topology |
|
| Transceiver: |
|
... |
EMI, complies with FCC Part 15, Class A; UL recognized; VDE: EMI compliant |
|
| Data Rate: |
|
... |
200 ms data transfer rate with 20 loudspeakers |
|