(2) CQ-1's @ 70° Horizontal Splay
To download this document in Adobe
Acrobat format, click here.
Array Coverage and SPL
Coverage:
Vertical 40° Horizontal 150°
Maximum SPL At 1 Meter:
Peak 137 dB
Base Specifications
Frequency Range (Free Field) 40 Hz to 18 kHz
Weight (Before Rigging) 260 lbs. (117.2 kg)
Measurement Notes:
Frequency range constitutes the usable bandwidth after on-axis normalization.
Coverage angles measured as the -6 dB (1/4 power) points from the normalized
on-axis frequency response averaged over the band from 125 to 8k Hz. All
measurements made at 4 Meters in an anechoic chamber using the Multi-purpose
Acoustic Prediction Program (M.A.P.P.)® at 1/36 octave bands and confirmed
at 8 meters outside using pink noise and measured in 1/24 octave bands with
SIM® System II.
Date: 10.31.97
Doc#: 01.990.101.61
Rev. A
2832 San Pablo Ave. Berkely, CA 94702 Phone: 510-486-1166 Fax: 510-486-8356 email: techsupport@meyersound.com